Specifications |
|
ECG |
|
Lead type |
3-lead or 5-lead selectable |
Lead selection, 3-lead |
I, II, III |
Lead selection, 5-lead |
I, II, III, aVR, aVL, aVF, V |
HR measurement |
Adult / pediatric: 15 bpm – 300 bpm Neonatal: 15 bpm – 300 bpm Step: 1 bpm |
HR accuracy |
±5 bpm or ±1 %, whichever is greater |
Arrhythmia |
21 calls |
ST measurement range |
-2.5 mV – +2.5 mV |
Waveform speed |
6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s |
Gain selection |
x 1/4, x 1/2, x 1, x 2, x 4, Auto |
Pacemaker detection |
Yes |
Protection |
Against electrosurgical interference and defibrillation |
Non-invasive blood pressure (NBP) |
|
Method |
Automatic oscillometric |
Parameters |
SYS/DIA/MAP/Pulse Rate |
Operating mode |
Manual/Auto/STAT |
Auto measure intervals |
3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes |
Units |
mmHg/kPa |
Cuff pressure range, adult / pediatric |
0 – 300 mmHg ( 0 kPa – 40.0 kPa) |
Cuff pressure range, neonate |
0 – 150 mmHg ( 0 kPa – 20.0 kPa) |
Systolic measurement range, adult/ pediatric |
30 mmHg – 254 mmHg (4.0 kPa – 33.9 kPa) |
Systolic measurement range, neonate |
30 mmHg – 135 mmHg (4.0 kPa – 18.0 kPa) |
Diastolic measurement range, adult / pediatric |
10 mmHg – 220 mmHg (1.3 kPa – 29.3 kPa) |
Diastolic measurement range, neonate |
10 mmHg – 110 mmHg (1.3 kPa – 14.7 kPa) |
MAP measurement range, adult / pediatric |
20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa) |
MAP measurement range, neonate |
20 mmHg – 125mmHg (2.7 kPa – 16.7kPa) |
Accuracy, maximum standard deviation |
8 mmHg (1.1 kPa) |
Accuracy, mean error |
±5 mmHg (±0.7 kPa) |
Pulse rate range |
40 bpm – 240 bpm |
Pulse rate accuracy |
±5bpm or ±5%, whichever is greater |
SpO2 (Philips SpO2 technology) |
|
Measurement range |
0 – 100 % |
Accuracy |
70 % – 100 %, depends on sensor; 0 – 69 %, unspecified |
Waveform speed |
6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Pulse rate range |
30 bpm – 300 bpm |
Pulse rate accuracy |
±2 bpm or ±2%, whichever is greater |
Perfusion index |
Yes |
Respiration (RESP) |
|
Measurement method |
Thoracic impedance |
Measurement range |
0 rpm – 150 rpm |
Accuracy |
0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm |
Waveform speed |
6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined |
Gain selection |
x 1/2, x 1, x 2 |
Apnea alarm |
Yes, 10 – 60 s |
Work mode |
Auto or manual (threshold) |
RESP lead |
RA-LL |
Temperature (TEMP, 2-channel) |
|
Measurement range |
0 – 50℃ (32℉ – 122℉) |
Resolution |
0.1℃ (0.2℉) |
Accuracy |
±0.1℃ (±0.2℉) (without sensor) |
Units |
℃ / ℉ |
Minimum measuring time |
Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes |
Capnopgraphy (etCO2, optional) |
|
Method |
Microstream, infrared absorption (Oridion) |
Parameters |
awRR, etCOâ‚‚, inCOâ‚‚ |
Measurement range |
0 – 99 mmHg (0 kPa – 13.2 kPa) |
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa) |
±2 mmHg (±0.28 kPa) |
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa) |
± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa) |
awRR range |
0-150 rpm |
awRR accuracy, 3 rpm – 70 rpm |
±1 rpm |
awRR accuracy, 71 rpm – 120 rpm |
±2 rpm |
awRR accuracy, 121 rpm – 150 rpm |
±3 rpm |
Invasive Blood Pressure |
|
Accuracy |
±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater |
Invasive blood pressure (IBP, 2-channel, optional) |
Parameters |
SYS/DIA/MAP/Pulse Rate |
Measurement range |
-50 – 400 mmHg (-6.6 kPa – 53.3 kPa) |
Waveform speed |
6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Resolution |
1 mmHg (0.13 kPa) |
Units |
mmHg/kPa/cmHâ‚‚O |
Transducer sensitivity |
5 uV/V/mmHg |
Pulse rate range |
30 bpm – 254 bpm |
Pulse rate accuracy |
±2bpm or ±2%, whichever is greater |
Sampling rate |
62.5 samples per second |
Recorder (optional) |
|
Type |
Built-in thermal recorder, 3 channels |
Print mode |
Real-time recording, timed recording, alarm-activated recording |
Print speed |
Auto, 12.5 mm/s, 25 mm/s, 50 mm/s |
Display |
|
Type |
Color TFT LCD, 4:3 |
Size |
10.4+611:631″ |
Resolution |
800 x 600 pixels |
Channels |
Max 11 channels (auto waveform channel height adjustment) |
Power supply |
|
AC power input |
100 – 240 VAC, 50/60 Hz |
Battery |
Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery) |
Weight and dimensions |
|
Net weight |
Approx. 3.5 kg without battery |
Dimensions (w x d x h) |
316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.) |
Safety approval and quality system |
|
Safety standard |
IEC 60601-1-2:2014 |
Electromagnetic environment |
IEC 60601-1-2:2000/A1:2014 |
Quality system |
ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC |
Water proof |
IPX1 |
Data review and storage |
|
Data review and storage |
1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 – alarm & arrhythmia events |
External interface (standard) |
|
External interface |
ECG analog output VGA output Nurse call LAN USB |
Cardiac Output (optional) |
|
Measurement method |
Right heart thermodilution |
Measurement range |
0.1 l/min – 20.0 l/min |
Measurement accuracy |
±0.2 l/min or ±10 %, whichever is greater |
Blood temperature range |
27℃ – 43℃ (80.6℉ – 109.4℉) |
Blood temperature accuracy |
± 0.1℃ |
Injection temperature |
0℃ – 27℃ (32℉ – 80.6℉) |