AK 98 Hemodialysis Machine
Specification
To help you find the balance between optimizing patient safety and managing organizational quality, the AK 98 framework has been developed. This hemodialysis monitor has numerous features and functions that allow you to deliver high-quality treatments reliably and efficiently when combined with our therapy options.
- Touch screen: A modern user-friendly touch screen guarantees quick and effective implementation of each and every session.
- Diascan function: allows real-time analysis of the efficacy of dialysis to help you meet your goals for care
- Alarms: The external alert light helps you to keep alarms in focus at all times.
- Treatments Period: The enhanced method of planning & disinfection helps to minimize the time between treatments
Blood flow management:
- Double-needle flow rate: 0 and 20 to 500 mL/min
- Single needle flow rate: 0 and 20 to 500 mL/min
- Pressure managed flow rate: 0 to 500 mL/min.
Supervision of blood circuit pressures:
- Arterial pressure: from -700 to +750 mmHg
- Venous pressure: between -700 and +750 mmHg
Detection of Air:
- Method: Detector of ultrasound
- The scale of drip chamber: diameter 22 mm
Pump with heparin syringe:
- Rate of flow: 0 to 10 mL/h
- Bolus Heparin Feature
- The volume of a bolus: 0 to 10 m
- Programmable stop time, read-out cumulative volume
Supplying Water:
- Pressure inlet: 0.12 to 0.6 MPa (1.2 to 6 bar)
- The temperature of the inlet water during treatment: 5 to 30 °C
The efficiency of inlet water: The fluid must conform with relevant regulations and ISO 139599 as a minimum.
Preparation of Dialysis Fluid and Control:
- Flow rate: 300-700 mL/min (a 20 mL/min step)
- Na+ 130 to 150 mmol/L, HCO3- 20 to 40 mmol/L Bicarbonate
range: - (Na+, HCO3-, UF) Profiling
- Standby Mode Focus
Regulation of Ultrafiltration:
- Amount of UF: Customizable, from 0 to 10.00 L
- Precision: ± 50 mL/h ± 1% UF rate: 0 to 4 L/h
- Independent supervision for ultrafiltration
Detection of Blood Leakages:
- Method: Infrared light Infrared light
- Disinfection and purification
- The automated method of disinfection with water treatment systems from Gambro
- Heat disinfectant, citric acid liquid, or CLEAN CART Short heat citric disinfectant disinfectant
- Chemicals: peracetic acid, hypochlorite sodium,
- Log of Disinfection
Power Supply
- The voltage of mains: 115, 230V
- Frequency: between 50 and 60 Hz
- Consumption of power: Max 2025W at 230V, 1575W at 115V
Sizes and weight
- Width: 345 mm computer, 585 mm stand
- Depth: 600 mm machine, 620 mm stand
- height: 1305 mm
- Weight: Ca. 70 kilograms (without options)
Operating environment:
- The temperature in the environment: 18 to 35 °C
- Relative humidity: 15 percent RH to 85 percent
- The pressure of air: Up to avg. 2500 meters more than sea level
(70 to 106 kpa)
Reviews