You can find Patient Monitor in BMA Bazar, an online store for Medical Equipment and Devices in Bangladesh. We deliver both inside and outside Dhaka, Bangladesh. BMA Bazar is an online store for medical Equipment, Devices, Accessories, Hospital furniture in Bangladesh. Pay using bank transfer, Visa or Master card and other mobile banking methods.

  • Bionet BM5 Patient Monitor-Korea

    0 out of 5
    (0)

    Bionet BM5 Patient Monitor

    Features:

    Brand Bionet
    Model BM 5
    Condition New
    Warranty 12 month(s)
    Origin Russia
    Category Patient Monitor
    Pulse Rate Range 0-300 bpm
    Display 10.4 inch
    Brand Bionet
    Frequency 50-60 Hz
    Resolution 800×600 Pixel
    Dimensions 270x250x184.5 mm

     

    SKU: n/a
  • Cavent Patient Monitor – Curative

    0 out of 5
    (0)

    Cavent Patient Monitor – Curative

    The world’s first innovative high-performance patient monitor with patent-pending technology that seamlessly interacts with ventilators to deliver sophisticated cardiopulmonary care from a single stage.

    Feature
    Brand Curative
    Model Cavent
    Measured parameter TEMP, ECG, RESP, NIBP, IBP, SpO2
    Applications Intensive care
    Configuration  Portable
    Patient type Pediatric
    Screen size 12 in
    SKU: n/a
  • Classic-120 Multi-Parameter Patient Monitor

    0 out of 5
    (0)

    Classic-120 Multi-Parameter Patient Monitor

    ECG Heart rate display range 15bpm ~ 350bpm
    Heart rate display accuracy ± 1% or ± 2bpm, whichever is greater
    Sweeping speed 12.5mm/s, 25mm/s, 50mm/s
    Sensitivity selection 1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV
    CMRR ≥ 89dB
    RESP Measuring range 0rpm~120rpm
    Accuracy ±5% or ±2 rpm
    Alarm limits setting range 0rpm~120rpm
    TEMP Measuring range 25.0℃ ~45.0℃
    Measuring accuracy ±0.2℃
    Responding time ≤150s
    NIBP Measuring method Oscillometric Technique
    Measuring range 0 mmHg~300mmHg
    Accuracy Maximal mean difference ±5 mmHg
    Maximal standard deviation 8 mmHg
    Measurement range Adult SYS 40 ~ 255 mmHg
    MAP 20 ~ 215 mmHg
    DIA 10 ~ 195 mmHg
    Pediatric patient SYS 40 ~ 200 mmHg
    MAP 20 ~ 165 mmHg
    DIA 10 ~ 150 mmHg
    Neonate SYS 40 ~ 135 mmHg
    MAP 20 ~ 110 mmHg
    DIA 10 ~ 95 mmHg
    SpO2 Measuring range 35%~100%
    Low perfusion capability 0.4%~5%
    Accuracy Not greater than 3% for SpO2 range from 70% to 100%
    PR Measuring range 30bpm~240bpm
    Measuring accuracy ±2bpm or ±2%, whichever
    SKU: n/a
  • Contec CMS6800 6 Parameter 10” Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer

    0 out of 5
    (0)

    Contec CMS6800 6 Parameter Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer

    Specifications:

    ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s
    HR: Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH
    RESPIRATION Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s.
    NIBP Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode
    SpO2 Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified.
    PR Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher
    TEMP Channel: dual-channel
    Measurement and alarm range: 0 ~ 50ºC
    Resolution: 0.1 ºC
    Accuracy: ±0.1 ºC
    EtCO2 Method: Sidestream or Mainstream
    CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes.
    IBP Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added.

    Accessories

    • SpO2 test for adult fingertips (5-pin)
    • NIBP adult cuff
    • NIBP extension pipe
    • ECG lead cable
    • ECG electrode
    • Temperature probe
    • Power cord

    Physical characteristic

    • Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H)
    • Weight: 3.6 Kg

    SKU: n/a
  • Contec CMS9000 6 Parameter 12” Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer

    0 out of 5
    (0)

    Contec CMS9000 6 Parameter Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer

    Specifications:

    ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s
    HR: Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH
    RESPIRATION Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s.
    NIBP Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode
    SpO2 Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified.
    PR Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher
    TEMP Channel: dual-channel
    Measurement and alarm range: 0 ~ 50ºC
    Resolution: 0.1 ºC
    Accuracy: ±0.1 ºC
    EtCO2 Method: Sidestream or Mainstream
    CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes.
    IBP Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added.

    Accessories

    • SpO2 test for adult fingertips (5-pin)
    • NIBP adult cuff
    • NIBP extension pipe
    • ECG lead cable
    • ECG electrode
    • Temperature probe
    • Power cord

    Physical characteristic

    • Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H)
    • Weight: 3.6 Kg

    SKU: n/a
  • Digital Philips Goldway GS20 Multipara Patient Monitor, Screen Size: 10.4 Inch

    0 out of 5
    0 out of 5
    (0)

    Digital Philips Goldway GS20 Multipara Patient Monitor, Screen Size: 10.4 Inch

    Specifications
    ECG
    Lead type 3-lead or 5-lead selectable
    Lead selection, 3-lead I, II, III
    Lead selection, 5-lead I, II, III, aVR, aVL, aVF, V
    HR measurement Adult / pediatric: 15 bpm – 300 bpm Neonatal: 15 bpm – 300 bpm Step: 1 bpm
    HR accuracy ±5 bpm or ±1 %, whichever is greater
    Arrhythmia 21 calls
    ST measurement range -2.5 mV – +2.5 mV
    Waveform speed 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s
    Gain selection x 1/4, x 1/2, x 1, x 2, x 4, Auto
    Pacemaker detection Yes
    Protection Against electrosurgical interference and defibrillation
    Non-invasive blood pressure (NBP)
    Method Automatic oscillometric
    Parameters SYS/DIA/MAP/Pulse Rate
    Operating mode Manual/Auto/STAT
    Auto measure intervals 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
    Units mmHg/kPa
    Cuff pressure range, adult / pediatric 0 – 300 mmHg ( 0 kPa – 40.0 kPa)
    Cuff pressure range, neonate 0 – 150 mmHg ( 0 kPa – 20.0 kPa)
    Systolic measurement range, adult/ pediatric 30 mmHg – 254 mmHg (4.0 kPa – 33.9 kPa)
    Systolic measurement range, neonate 30 mmHg – 135 mmHg (4.0 kPa – 18.0 kPa)
    Diastolic measurement range, adult / pediatric 10 mmHg – 220 mmHg (1.3 kPa – 29.3 kPa)
    Diastolic measurement range, neonate 10 mmHg – 110 mmHg (1.3 kPa – 14.7 kPa)
    MAP measurement range, adult / pediatric 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa)
    MAP measurement range, neonate 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa)
    Accuracy, maximum standard deviation 8 mmHg (1.1 kPa)
    Accuracy, mean error ±5 mmHg (±0.7 kPa)
    Pulse rate range 40 bpm – 240 bpm
    Pulse rate accuracy ±5bpm or ±5%, whichever is greater
    SpO2 (Philips SpO2 technology)
    Measurement range 0 – 100 %
    Accuracy 70 % – 100 %, depends on sensor; 0 – 69 %, unspecified
    Waveform speed 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
    Pulse rate range 30 bpm – 300 bpm
    Pulse rate accuracy ±2 bpm or ±2%, whichever is greater
    Perfusion index Yes
    Respiration (RESP)
    Measurement method Thoracic impedance
    Measurement range 0 rpm – 150 rpm
    Accuracy 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm
    Waveform speed 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined
    Gain selection x 1/2, x 1, x 2
    Apnea alarm Yes, 10 – 60 s
    Work mode Auto or manual (threshold)
    RESP lead RA-LL
    Temperature (TEMP, 2-channel)
    Measurement range 0 – 50℃ (32℉ – 122℉)
    Resolution 0.1℃ (0.2℉)
    Accuracy ±0.1℃ (±0.2℉) (without sensor)
    Units ℃ / ℉
    Minimum measuring time Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes
    Capnopgraphy (etCO2, optional)
    Method Microstream, infrared absorption (Oridion)
    Parameters awRR, etCO₂, inCO₂
    Measurement range 0 – 99 mmHg (0 kPa – 13.2 kPa)
    Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa) ±2 mmHg (±0.28 kPa)
    Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa) ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa)
    awRR range 0-150 rpm
    awRR accuracy, 3 rpm – 70 rpm ±1 rpm
    awRR accuracy, 71 rpm – 120 rpm ±2 rpm
    awRR accuracy, 121 rpm – 150 rpm ±3 rpm
    Invasive Blood Pressure
    Accuracy ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater
    Invasive blood pressure (IBP, 2-channel, optional)
    Parameters SYS/DIA/MAP/Pulse Rate
    Measurement range -50 – 400 mmHg (-6.6 kPa – 53.3 kPa)
    Waveform speed 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
    Resolution 1 mmHg (0.13 kPa)
    Units mmHg/kPa/cmH₂O
    Transducer sensitivity 5 uV/V/mmHg
    Pulse rate range 30 bpm – 254 bpm
    Pulse rate accuracy ±2bpm or ±2%, whichever is greater
    Sampling rate 62.5 samples per second
    Recorder (optional)
    Type Built-in thermal recorder, 3 channels
    Print mode Real-time recording, timed recording, alarm-activated recording
    Print speed Auto, 12.5 mm/s, 25 mm/s, 50 mm/s
    Display
    Type Color TFT LCD, 4:3
    Size 10.4+611:631″
    Resolution 800 x 600 pixels
    Channels Max 11 channels (auto waveform channel height adjustment)
    Power supply
    AC power input 100 – 240 VAC, 50/60 Hz
    Battery Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery)
    Weight and dimensions
    Net weight Approx. 3.5 kg without battery
    Dimensions (w x d x h) 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.)
    Safety approval and quality system
    Safety standard IEC 60601-1-2:2014
    Electromagnetic environment IEC 60601-1-2:2000/A1:2014
    Quality system ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC
    Water proof IPX1
    Data review and storage
    Data review and storage 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 – alarm & arrhythmia events
    External interface (standard)
    External interface ECG analog output VGA output Nurse call LAN USB
    Cardiac Output (optional)
    Measurement method Right heart thermodilution
    Measurement range 0.1 l/min – 20.0 l/min
    Measurement accuracy ±0.2 l/min or ±10 %, whichever is greater
    Blood temperature range 27℃ – 43℃ (80.6℉ – 109.4℉)
    Blood temperature accuracy ± 0.1℃
    Injection temperature 0℃ – 27℃ (32℉ – 80.6℉)
    SKU: n/a
  • ECG PATIENT MONITOR YK-8000G

    0 out of 5
    (0)

    ECG PATIENT MONITOR YK-8000G

    YK-8000 G multi-parameter patient monitor is a solid patient monitor with long term service.

    Feature:
    Brand Yonker
    Model YK-8000G
    Measured parameter ECG, RESP, TEMP, EtCO2, NIBP, IBP, SpO2
    Applications Intensive care, anesthesia
    Screen size 12.1 inch
    Indication Indication of Incorrect manipulation and malfunction
    Time  Detection Real-time S-T segment analysis, pace-maker detection
    Display 12.1″high resolution color TFT LCD display.
    Standard parameters 6 Standard parameters: ECG, RESP, NIBP, SPO2, 2-TEMP, PR/HR.

    SKU: n/a
  • Multi-Parameter Patient Monitor – 8000B

    0 out of 5
    (0)

    Multi-Parameter Patient Monitor – 8000B

    Multi-Parameter Patient Monitor – 8000G is a very popular and quality medical product using all over the world.

    Brand YK-8000B
    Display 12.1-inch high-resolution color TET LCD
    Alarms 3-level audio/visual
    Working Capability 2-hour
    Battery Built-in rechargeable lithium battery
    Size 12 * 11.4 * 6.4 inch
    Weight 8.8 lb
    Electrical Specification 100-240v AC, 50/60Hz, Max Input Power: 70VA
    Battery 11.1V  2200mAh rechargeable lithium battery
    Standard configuration SpO2, PR, NIBP, ECG, RESP, TEMP
    Optional Configuration Nellcor SpO2, 2-IBP, ETCO2, Touch screen, Built-in Thermal Printer
    Various interfaces standard screen, trend screen, oxy CRG screen, NIBP list screen, big front screen.
    SKU: n/a
  • Multi-Parameter Patient Monitor YK-9000A

    0 out of 5
    (0)

    Multi-Parameter Patient Monitor YK-9000A

    Brand: Yonker
    Model: YK-9000A

    Technical Specifications:
    Display 12.1” Color TFT Screen

    IBP Method: Oscillometry
    Modes: Manual/Auto/ Comtinuous
    Auto measure time: Adjustable
    Measurement range:10-270mmHg
    ECG Lead mode: 3-lead or 5-lead
    Lead selection: I;II;III,avR;avF;V
    Heart rate range: Adult:15-300bpm;Pediatric/Neonatal:15-300bpm
    ECG waveform: 2 channels
    Accuracy: ±1 bpm or ±1%,which is greater
    S-T segment detection; measurement range: 2.0mv~2.0mv
    Alarm: Yes, audible and  visual alarm, alarm events review
    SPO2 Measurement range:0-100%
    Accuracy:70-100%,±2%,0-69%,upspecified
    Auto measure time: Adjustable
    Pulse Rate Range:20-254bpm
    Accuracy: ±3bpm
    Respiration Method: RA-LL impedance
    Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm
    Apnca alarm: Yes
      Temperature Range:0-500
    Accuracy: ± 0.10
    Channel: Dual-channel

    Warranty: 1 Year

    Standard accessories

    • Spo2 sensor adult 1 pcs
    • NIBP CUFF& Hose pipe 1 set
    • ECG cable 1 pcs
    • Temp Sensor 1 pcs
    • User manual 1 pcs
    SKU: n/a
  • Multi-parameter patient monitor, BT-750, Bistos

    0 out of 5
    (0)

    Multi-parameter patient monitor, BT-750, Bistos

    Display: 10.4 Inch Multi-Parameter Color Patient
    Monitor:  2ch ECG, SpO2, NIBP, 2ch IBP, 2ch Temp, Respiration, Optional Built-in EtCO2
    Built-In EtCO2 Module:  Built-In EtCO2 Mode (EtCO2 module is inside of monitor Respironics sidestream module
    Easy to use: Selectable 5 waveform / 4 waveform / 3 waveform Display/Enabled / disabled /parameters, the color, and font of each parameter are changeable changeable
    ECG Analysis: 12 kinds of arrhythmia analysis ST Level & PVC count real-time display
    IBP:  ABP / CVP / PAP / LAP
    Multi-national Software:  English, French, German, Spanish, Italian, Portuguese
    Transportable: Up to 4 hours use with battery Less than 3 kg of lightweight
    Quick start-up: Less than 2 seconds
    Trend data: 72 hours of graphics and tabular trend Interface RS-232 port and LAN port

     

    SKU: n/a
  • Northern Meditech Venus Critical Care Patient Monitor

    0 out of 5
    (0)

    Northern Meditech Venus Critical Care Patient Monitor

    Specifications:

    Display:
    15.6″ color TFT screen
    Resolution: 1366*768 dpi
    Number of traces: 12 waveforms

    Battery:
    Rechargeable lithium battery

    Networking Wired Or Wireless:

    LAN: 1 standard RJ45 Port
    WLAN: IEEE802.11 b/g/n
    USB: 2 USB connectors
    SO: 1 SD card Socket
    VGA: 1 standard color VGA monitor connector
    Output: 1 standard connector for Nurse Call, Defib Sync Analog Output

    Recorder (Optional)
    Built-in, thermal dot array
    Waveform: 3 channels
    Paper width: 50mm
    Print speed: 12.5 mm/s, 25mm/s, 50mm/s

    ECG:
    Lead Type: 3-lead, 5-lead, 12-lead
    ECG waveform: 2 channels, 7 channels, 12 channels
    Gain selection: x0.25, x0.5; x1; x2
    Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
    Filter: Diagnostic mode: 0.05-150Hz
    Monitoring mode: 0.5-40 Hz
    Surgery mode: 1-20Hz
    Notch: 50Hz, 60Hz
    Heart Rate range: Adult: 15-300bpm;
    Pediatric! Neonate: 15-350bpm;
    Accuracy: ±1 bpm or ±1 %, whichever is greater
    Resolution: ±1bpm

    Respiration:
    Method: Trans-thoracic impedance
    Operation modes: Auto/ Manual
    Measurement range: Adult: 0-120 bpm;
    Neonate/Pediatric: 0-150 bpm
    Apnea alarm delay: 1Os, 15s, 20s, 25s, 30s, 35s, 40s
    Apnea Alarm: Selectable
    Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s

    Sp02:
    Measurement range: 0-100%
    Resolution: 1%
    Accuracy: ±2% (70-100% Adult/Pediatric);
    ±3% (70-100% Neonate);
    0-69% unspecified
    Refreshing rate: 1s

    Masimo SET®
    SP02(0ptional)
    Accuracy: ±2% (70-100% Adult/Pediatric, non-motion,low perfusion);
    ±3% (70-100% Neonate, non-motion);
    ±3% (70-100% motion);
    0-69% unspecified

    Pulse Rate:
    Range: 0-254 bpm
    Resolution: 1 bpm
    Accuracy: ±3bpm (non-motion)
    ±5bpm (motion)
    Refreshing rate: 1s

    NIBP:
    Method: Automatic oscillometric
    Operation modes: Manual/Auto I STAT
    Measurement unit: mmHg/kPa selectable
    Measurement types: Systolic, Diastolic, Mean
    Measurement range:
    Range of systolic pressure: Adult Mode 40 -270 mmHg
    Pediatric Mode 40 – 200 mmHg
    Neonatal Mode 40 – 135 mmHg
    Range of diastolic pressure: Adult Mode 10 – 210 mmHg
    Pediatric Mode 10 – 150 mmHg
    Neonatal Mode 10 – 100 mmHg
    Range of mean pressure: Adult Mode 20- 230mmHg
    Pediatric Mode 20 – 165mmHg
    Neonatal Mode 20 – 110mmHg
    Accuracy: Max mean error: ±5 mmHg
    Measurement Interval: 1 ,2,3,4,5, 10, 15,30,60,90, 120,180,240,
    480minutes
    Over-pressure protection: Double safety protection
    Cuff pressure range: 0-280 mmHg
    Resolution: 1 mmHg

    Temperature:
    Accuracy: ±0.1 “C or ±0.2 “F (without probe)
    Measurement range: 0-50″C (32 to 122 “F)
    Channel: Two-channels
    Resolution: 0.1 “C
    Parameters: T1 , T2 and TD

    IBP (Optional):

    Channel: 2-channel
    Measurement types: Systolic, Diastolic, Mean
    Range:OmmHg-300mmHg
    Resolution: 1 mmHg
    Accuracy: ±2% or ±1 mmHg, whichever is greater (without sensor)
    Sensitivity: 5uV/mmHgN
    Impedance range: 300 to 3000

    C.O. (Optional):
    Method: Thermodilution
    Range: C.O.: 0.1 to 20Umin
    TB: 23 to 43’C
    T1: 0 to 27’C
    Accuracy : C.0.:±5% or ±0.1Umin, whichever is greater
    TB, T1: ±0.1 ‘C (without sensor)

    Phasein ISA:
    SidestreamC02 (Optional)
    Warm-up time: Full accuracy within 10 seconds
    Sampling flow rate: 50ml/min (+/-10ml/min)
    Accuracy: ± (0.2 % + 2 % of the reading)
    Measurement Range: 0 -15%
    Rise time: 200ms, typical at 50ml/min flow rate

    Respiration:
    Method: Trans-thoracic impedance
    Operation modes: Auto/ Manual
    Measurement range: Adult: 0-120 bpm;
    Neonate/Pediatric: 0-150 bpm
    Apnea alarm delay: 1Os, 15s, 20s, 25s, 30s, 35s, 40s
    Apnea Alarm: Selectable
    Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s

    Pulse Rate:
    Range: 0-254 bpm
    Resolution: 1 bpm
    Accuracy: ±3bpm (non-motion)
    ±5bpm (motion)
    Refreshing rate: 1s

    Temperature:
    Accuracy: ±0.1 “C or ±0.2 “F (without probe)
    Measurement range: 0-50″C (32 to 122 “F)
    Channel: Two-channels
    Resolution: 0.1 “C
    Parameters: T1 , T2 and TD

     

    SKU: n/a
  • NT3 Series Multiparameter Patient Monitor

    0 out of 5
    (0)

    NT3 Series Multiparameter Patient Monitor

    Features

    Frequency Response 0.5~40Hz
    Sweep Speed(mm/sec)  12.5, 25, 50
    Heart Rate Range 0~350bpm
    Heart Rate Accuracy ±1%
    Respiration Rate Measurement Range : 0~120bpm
    Respiration Rate Accuracy ±1bpm or 5%(choice max)
    Respiration Rate Resolution  1bpm
    CO2 Measurement Range 0~10.0%
    CO2 Accuracy ±2mmHg or 5%(choice max)
    CO2 Response Time  180ms
    SKU: n/a
  • NT3C Multiparameter Patient Monitor

    0 out of 5
    (0)

    NT3C Multiparameter Patient Monitor

    Features

    Frequency response Monitor: 0.5~40 Hz
    Heart rate range  0-350 BPM
    Heart rate accuracy ± 1 %
    ST segment deviation analysis -0.8~+0.8mV
    ST accuracy ±0.02mv
    SPO2 measurement range 0 – 100 %
    Accuracy ±2% at 70~100%
    Temperature 5~40 ℃ -20~70 ℃
    Relative humidity ≤ 80% ≤ 95%
    Input 98-260 V AC, 50/60Hz
    Consumption ≤ 80VA
    SKU: n/a
  • Patient Monitor Beta 12

    0 out of 5
    (0)

    Patient Monitor Beta 12

    Brand Name Chenwei
    Model Number Beta 12
    Place of Origin Guangdong, China
    Product name 15inch patient monitor
    Standard ECG, SPO2, NIBP, Temp, Resp., HR
    Optional EtCO2, 2IBP, Massimo SPO2, Printer, etc.
    Display 12.1 inch TFT screen
    Optional Accessories Aluminum trolley, wall mount stand
    Size 300*170*305 mm
    Warranty 1 Year
    Certificate CE ISO
    Type

    Examination Therapy Equipment

    Features

    • 12.1″ TFT screen.6 standard parameters.
    • 32-levels sound volume adjustment.
    • 10 levels of brightness adjustment.Maximum 168 hours of graphic and tabular trends of all parameters.
    • Back up battery for 5 hours of continuous working time.
    • ECG, SPO2, NIBP, Temp, Resp, HR for standard.
    • Suitable for use in vehicle.

    Warranty: 1 Year

    SKU: n/a
  • Patient Monitor Beta 15

    0 out of 5
    (0)

    Patient Monitor Beta 15

    Brand Name Chenwei
    Model Number Beta 15
    Place of Origin Guangdong, China
    Product name 15inch patient monitor
    Standard ECG, SPO2, NIBP, Temp, Resp., HR
    Optional EtCO2, 2IBP, Massimo SPO2, Printer, etc.
    Display 15 inch TFT screen
    Optional Accessories Aluminum trolley, wall mount stand
    Size 300*170*305 mm
    Warranty 1 Year
    Certificate CE ISO
    Type

    Examination Therapy Equipment

    Features

    • 15″ TFT screen.6 standard parameters.
    • 32-levels sound volume adjustment.
    • 10 levels of brightness adjustment.Maximum 168 hours of graphic and tabular trends of all parameters.
    • Back up battery for 5 hours of continuous working time.
    • ECG, SPO2, NIBP, Temp, Resp, HR for standard.
    • Suitable for use in the vehicle..

    Warranty: 1 Year

    SKU: n/a
  • Patient Monitor SPO2 Sensor, Adult

    0 out of 5
    (0)

    Patient Monitor SPO2 Sensor, Adult

    This sensor is consistent with the monitor and utilizes infrarot light to assess hemoglobin oxygen saturation in the blood of the artery. The sensor connects to the device providing measurements that can be printed and stored in records of patients.

    Use For Brand

    • Yonker
    • Enen
    • Heal Force
    • Mindray
    • Bionet
    • Philips
    • Aesmedical

    SKU: n/a
  • Patient Monitor SPO2 Sensor, Pediatric/Child

    0 out of 5
    (0)

    Patient Monitor SPO2 Sensor, Pediatric/ child

    This sensor is consistent with the monitor and utilizes infrarot light to assess hemoglobin oxygen saturation in the blood of the artery. The sensor connects to the device providing measurements that can be printed and stored in records of patients.

    Use For Brand

    • Yonker
    • Enen
    • Heal Force
    • Mindray
    • Bionet
    • Philips
    • Aesmedical

     

    SKU: n/a
  • Philips Efficia CM12 Patient Monitor

    0 out of 5
    0 out of 5
    (0)

    Philips Efficia CM12 Patient Monitor

    Specification
    Brand PHILIPS
    Model Efficia CM12
    Display Size 12″ LCD
    Resolution 1280 x 800
    Basic Parameter ECG, SPO2, NIBP
    Temperature Range 0–40°C (32–104°F)
    Humidity Range 15–95% Relative Humidity
    Ingress Protection IP21
    Power Consumption < 75 Watts.
    Weight < 5.0 kg (11.0 lb).
    Indicator Alarm, ON, Error, External
    Power & Battery
    USB 2.0 & RS232 Available
    ETCO2 Optional
    IBP Optional
    Cardiac Output (CO) Optional
    SKU: n/a
  • Philips IntelliVue MX430 Modular Patient Monitor

    0 out of 5
    0 out of 5
    (0)

    Philips IntelliVue MX430 Modular Patient Monitor Warranty- 1 year.

    Specification
    Brand PHILIPS
    Model IntelliVue MX 430
    Country of Origin Germany
    Display Size 12″ LCD
    Resolution 1280 x 800
    Basic Parameter ECG, SPO2, NIBP
    Temperature Range 0–40°C (32–104°F)
    Humidity Range 15–95% Relative Humidity
    Ingress Protection IP21
    Power Consumption <70 W average
    Weight 6.6 kg (14.6 lb)
    Indicator Alarm, ON, Error, External
    Power & Battery
    USB 2.0 & RS232 Available
    ETCO2 Optional
    IBP Optional
    Cardiac Output (CO) Optional
    SKU: n/a
  • RMS Patient Monitor p-515

    0 out of 5
    (0)

    RMS Patient Monitor p-515

    Product Name Patient Monitor
    Brand RMS
    NIBP Measurement range 10-300mmHg
    Pulse Rate Range 20-254bpm
    Usage/Application Hospital
    Display 8 Inch
    Display Size 12.1″
    Display color TFT color Display
    SKU: n/a
  • YK-8000C YONKER Multi-Parameter Patient Monitor

    0 out of 5
    (0)

    YK-8000C YONKER Multi-Parameter Patient Monitor

    Brand: Yonker
    Model: YK-8000C  

    Features:
    • Multi-parameter TET LCD color screen–8000C
    • 1-inch color monitor.
    • Lighter and thinner in design, user-friendly and portable.
    • Evaluation of the S-T section in real-time, identification of pacemakers.
    • Audio / visual warnings at 3 grades.
    • Efficient defibrillator and HF knife interference resistance.
    • Up to 400 NIBP teams, 6000 seconds, ECG waveform recall, 60 records of warning incidents, 7-day processing trend index.
    • Built-in lithium rechargeable battery with a 2-hour capacity.
    • Applicable ICU / CCU / OR wireless central monitoring system
    • Size: 12* 11.4* 6.4 inches
    • Weight: 8.8 lb
    • Electrical specification: 100-240v AC, 50/60Hz, total input power: 70VA
    • Battery: 11.1V  2200mAh rechargeable lithium battery

    Standard configuration:
    SpO2, PR/HR, NIBP, ECG, RESP, 2-TEMP

    Optional Configuration:
    Nellcor SpO2, 2-IBP, ETCO2, Touch screen, Built-in Thermal Printer

     Standard accessories

    • Spo2 sensor adult 1 pcs
    • NIBP CUFF& Hosepipe 1 set
    • ECG cable 1 pcs
    • Temp Sensor 1 pcs
    • User manual 1 pcs

    Warranty: 1 Year

    SKU: n/a
  • Yonker Multi-Parameter Patient Monitor – 8000A

    0 out of 5
    (0)

    Yonker Multi-Parameter Patient Monitor – 8000A

    Specifications

    Dimensions: 6.9 * 11.6 * 5.7 inches

    • Peso: 4.4 lb
    • Range of electricity: 100-240v AC, 50/60Hz, Max input power: 70VA
    • Battery: Lithium battery rechargeable to 11.1V 2000mAh
    • Regular Setup: SpO2, PR / HR, NIBP, ECG, RESP

    Optional Setup: TEMP / EtCO2, Nellcor SpO2, Thermal Printer

    • Rechargeable lithium battery built-in, capable of operating 2 hours.
    • Wireless, central ICU / CCU / OR monitoring system

    Package Include:

    • 1 x 8000A device
    • 1 x Li-Battery
    • 1 x Power line
    • 1 x Earth wire
    • 1 x User’s Manual
    • 1 x Blood oxygen probe (for SpO2, PR)
    • 1 x Blood pressure cuff (for NIBP)
    • 1 x ECG cable (for ECG, RESP)
    • 1 x Temperature probe (for Temperature)

     

    SKU: n/a
  • Yonker Multi-Parameter Patient Monitor IE-15

    0 out of 5
    (0)

    Yonker Multi-Parameter Patient Monitor IE-15

    Specifications:

    • 15” real color TFT screen
    • Resolution: 800*600
    • One alarm indicator (yellow/red)
    • One working indicator(green)
    • One battery charge state indicator (green)
    • Three modes in accordance with the alarm state.

    Power Requirements:

    AC:  100  ~240, 50Hz/60Hz

    DC: Built-in rechargeable battery

    Battery:

    • 4000mA 1v lithium battery
    • 2h operating after full charge
    • 5min operating after a low battery alarm.

    Dimension and Weight:

    Equipment:

    305mm  x 160mm x 287mm; 3.8  kg

    Package:

    380mm  x 350mm x 300mm; 6.1  kg

    SKU: n/a

Showing 1–24 of 26 results